Wildeye is a standard industrial telemetry device for collecting remote meter & sensor data for any device within cellular coverage. Connect a Wildeye to the In-situ Level TROLL, Aqua TROLL or Baro TROLL depth sensors to transfer depth and water quality data directly to the web. Note: The Rugged Troll series has different wiring, see here. SDI-12 is the recommended interface to connect up the In-Situ:
For full details of meter interface and wiring see details of each option below. |
|
||||
In-situ depth sensor with Wildeye Telemetry |
Wildeye SDI-12 Connection
Use a standard Wildeye WILD-M-R-NACS-NACS (Wildeye with solar option) or WILD-M-B-NACS (Wildeye with battery option) to connect a In-situ Level/Aqua/Baro TROLL using the SDI-12 interface.
For detailed wiring refer to wiring diagrams below.
Wildeye |
+ |
Optional Extension |
+ |
Wildeye Adapter |
+ |
Sensor Addon |
+ |
Depth Sensor |
WILD-M-R-NACS-NACS |
ACC-CAB-M12-EXT-5P-2M |
ACC-CON-M12-5POS-M-8 |
In-situ RuggedCable |
In-situ TROLL |
||||
Notes:Use WILD-M-B-NACS for long-life battery or WILD-M-R-NACS-NACS for solar. |
Notes:Choose optional extension cables from 2m to 30m length |
Notes:Wire the Wildeye M12 field connector to the RuggedCable stripped ends per below |
Notes:Part # CFG-SSTCCable, Stripped & Tinned with Male Connector |
Notes:The TROLL comes with built-in SDI12 |
Note! The Insitu Rugged Cable has 5 cores. If the Insitu cable does not have 5 cores, it is the wrong cable type!
Wildeye SDI-12 Wiring Details
Wire the ACC-CON-M12-5POS-M-8 field connector to the bare wires of the In-situ TROLL as follows:
Then, attach the ACC-CON-M12-5POS-M-8 adapter to the NACS cable of the WILD-M-B-NACS or WILD-M-R-NACS-NACS model.