Flow Meter Summary

Image result for netafim IRT meter

Manufacturer

Netafim

Models

Type

Inline propeller meter

Pulse Interface

  • Standard Register (pulse output capable)

  • Photo Diode Register (voltage output)

  • Multi-Purpose Electronic (MPE) Register 

Programming

 N/A

Battery Life Claimed

 N/A

Support Contact

 Dan Rodriguez

Straight Pipe Requirement 

 80mm, 100mm: 10 d before and 5 d after

150mm - 250mm: 10 (5) d before and 5 (3) d after meter

Pipe Sizes Supported

3”, 4”, 6”, 8” and 10” (80mm – 250mm)

Technical Manual

attached

 

Photographs

  • Photo Diode Register (voltage output)

Not assessed

  • Multi-Purpose Electronic (MPE) Register 

Not assessed


Site Assessment

  • Straight pipe installation requirement: 10 x diameter pipe upstream (before the meter) and 5 x diameter pipe

downstream (after the meter).

  • The meter may be installed in any position. For non-horizontal positions, the flow should be upwards.

  • Prior to installation of the meter, the pipeline should be thoroughly flushed.

  • Meter must be installed so that the pipe will be full of water at all times during metering.

  • Recommendation: Continuous Acting Air Vents of proper size and type be installed to eliminate air.

 

Pulse Output Connections

Meter Pulse Output Port:

A Netafim IRT Series meter has 3 different register types:

  • Standard Register (pulse output capable)

  • Photo Diode Register (voltage output)

  • Multi-Purpose Electronic (MPE) Register 

The same register fits into all the Netafim mechanial meter types (M Series, WMR Series, WST/WT Series, IRT Series)

Electrical Connections

  • Standard Register (pulse output capable)

A "Pulse Reed Switch" module must be installed onto the register to get pulse output. 

Function

Wildeye wire color

Netafim IRT

Ground

Black

Black

Counter 1

White

Red

 

  • Photo Diode Register (voltage output)

Not assessed

  • Multi-Purpose Electronic (MPE) Register 

Not assessed

Pulse Interface Details

  • Standard Register (pulse output capable)

Pulse Output Type: Reed Switch

Pulse Width: N/A

Pulse Weights:

  • Photo Diode Register (voltage output)

Not assessed

  • Multi-Purpose Electronic (MPE) Register 

Not assessed

 

Pulse Cable Options

There are <> options to connect the <> to the Wildeye:

a) 

b) 

Example Wildeye Plug types with "C" Channels:

MAC Plug

MCCD Plug  (C1 Channel)

 

Wildeye <> Cable

For 

Refer to Wildeye plug types with "C" channels above. 

<> Pulse Output Cable

 

Use OEM Parts for Pulse Connection

Series

 

Pulse Output Programming

Not Required -- pulse output rates are fixed according to the register type. 