Part number: P51105 · Issued: 12 November 2026
Key features
-
Digital SDI-12 output plugs directly into a Wildeye datalogger NACS connector, with no field wiring
-
Stainless steel probe for water, soil or air temperature
-
Probe tip and cable moulded as one sealed unit
-
IP68 rated assembly for submerged and outdoor installation
Overview
The Wildeye SDI-12 Temperature Probe measures water, soil or air temperature and plugs directly into the NACS connector on a Wildeye datalogger. The 6mm stainless steel probe housing is factory-wired to a Wildeye analogue convertor module, which converts the reading to SDI-12. There is no field wiring or scaling to set up. The probe tip and cable are moulded as a single sealed unit, and the full assembly is rated IP68 for submerged and outdoor installations. A 1 m cable runs between the probe and the convertor.
Specifications
Measurement
|
Resolution |
0.01°C (0 to 40°C) |
|---|---|
|
Accuracy |
±0.2°C (0 to 70°C) |
|
Output |
SDI12 |
Physical
|
Operating range |
−50°C to +105°C continuous |
|---|---|
|
Probe Housing |
Stainless steel, 6mm diameter |
|
Cable |
1m |
|
Ingress protection |
IP68 (probe, cable and convertor) |
Connection
|
Connector |
M12 male, 5 position |
|---|---|
|
Cable length |
1m |
|
Pin |
Wire colour |
Function |
|---|---|---|
|
1 |
Brown |
V+ |
|
2 |
White |
SDI12 |
|
3 |
Blue |
N/C |
|
4 |
Black |
GND |
|
5 |
Grey |
N/C |
Compatibility
|
Compatible loggers |
Wildeye -NACS plug |
|---|---|
|
Mywildeye.com Add Sensor template |
NTC thermistor | ACC-EXP-T.2 |
|
Add Sensor QR |
Use this QR code in the Wildeye App to add this sensor |