Skip to main content
Skip table of contents

Output Power

Introduction

Loggers might have a switched and/or a permanent output power supply to power external sensors. These power supplies have the following specifications.

Switched power output (SPO)

The SPO is switched on shortly before and during a log. The on period before a log is specified by each input's configuration. 

Parameter

Value

Comment

Voltage

15V DC ± 0.5V

Before September 2024, 12V was the default

Max Current

150 mA

25% margin for component variations

Operating mode

Switched

Controlled by logger, turned on when scheduled to take sensor reading

Continuous power output (CPO)

CPO is available on certain logger models - eg WILD-M-R-NCCS5-NAS

Parameter

Value

Comment

Voltage

5V DC

Max Current

25 mA

@ 0.2 V dropout

50 mA

@ 0.4 - 0.7 V dropout

Operating mode

Permanently on

The CPO is on continuously.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.